Фотографии | Производитель. Часть # | Доступность | Цены | Количество | Таблицы данных | Packaging | Series | ProductStatus | Type | DisconnectType | NumberofPositions | NumberofLevels | Terminal-Width | TerminationStyle | Current-IEC | Voltage-IEC | Current-UL | Voltage-UL | WireGaugeorRange-AWG | WireGaugeorRange-mm² | Features | Color |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
17175.4CONN TERM BLK DISCONNECT 8-22AWG |
3,005 | 12.99 |
RFQ |
![]() Datasheet |
Box | SSIK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.1mm | Screw | 10 A | 30V | 10 A | 600V | 8-22 AWG | 0.2-10mm² | LED | Black |
![]() |
0395960000CONN TERM BLK FEED THRU 12-22AWG |
4,953 | 12.52 |
RFQ |
![]() Datasheet |
Bulk | SAK | Active | Feed Through | - | 3 | 2; Connected | 6.0mm | Screw | 10 A | 24V | - | - | 12-22 AWG | 0.5-4mm² | LED | Beige |
![]() |
1198.2EARTH TERMINAL |
2,750 | 13.03 |
RFQ |
Box | SL | Active | Ground, Earth | - | 2 | 1 | 16.0mm | Screw | - | - | - | - | 2-12 AWG | 2.5-50mm² | - | Green, Yellow | |
![]() |
1449.2THREE-CONDUCTOR INSTALLATION TER |
1,891 | 13.04 |
RFQ |
![]() Datasheet |
Box | DLI | Active | Feed Through | - | 9 | 2 | 12.0mm | Screw | 24 A | 400V | - | - | 14-22 AWG | 0.2-4mm² | - | Beige |
![]() |
279-915/281-410COMPONENT TERMINAL BLOCK; 2-COND |
4,207 | 13.04 |
RFQ |
![]() Datasheet |
Box | - | Active | Feed Through | - | 2 | 1 | 4.0mm | Push In, Spring | 500 mA | - | - | - | 16-28 AWG | 0.08-1.5mm² | Diode | Gray |
![]() |
2006-86742-CONDUCTOR DISCONNECT/TEST TERM |
2,362 | 13.04 |
RFQ |
![]() Datasheet |
Box | TOPJOB®S | Active | Disconnect | Switch, Knife | 2 | 1 | 15.0mm | Push In, Spring | 30 A | 1500V | 30 A | 600V | 8-20 AWG | 0.5-10mm² | - | Blue |
![]() |
280-6784-CONDUCTOR SHIELD TERMINAL BLOC |
2,187 | 13.08 |
RFQ |
![]() Datasheet |
Box | - | Active | Ground, Earth | - | 4 | 1 | 5.0mm | Push In, Spring | - | - | - | - | 12-28 AWG | 0.08-2.5mm² | - | White |
![]() |
280-8384-CONDUCTOR SHIELD TERMINAL BLOC |
2,852 | 13.08 |
RFQ |
![]() Datasheet |
Box | - | Active | Ground, Earth | - | 4 | 1 | 5.0mm | Push In, Spring | - | - | - | - | 12-28 AWG | 0.08-2.5mm² | - | White |
![]() |
784-6072-CONDUCTOR GROUND TERMINAL BLOC |
2,700 | 13.08 |
RFQ |
![]() Datasheet |
Box | TOPJOB®S | Active | Ground, Earth | - | 2 | 1 | 10.0mm | Push In, Spring | - | - | - | - | 8-24 AWG | 0.2-10mm² | - | Green, Yellow |
![]() |
281-6162-CONDUCTOR FUSE TERMINAL BLOCK; |
3,943 | 13.09 |
RFQ |
![]() Datasheet |
Box | - | Active | Disconnect | Fuse | 2 | 1 | 8.0mm | Push In, Spring | 10 A | 800V | - | - | 12-28 AWG | 0.08-4mm² | - | Gray |
![]() |
280-5783-CONDUCTOR SENSOR/ACTUATOR TERM |
2,618 | 13.10 |
RFQ |
![]() Datasheet |
Box | - | Active | Feed Through, Isolated | - | 3 | 2; 1 Grounded | 6.0mm | Push In, Spring | 20 A | 400V | - | - | 12-28 AWG | 0.08-2.5mm² | - | Gray |
![]() |
1011.2FEED-THROUGH TERMINAL/BLOCK VERS |
4,258 | 13.11 |
RFQ |
![]() Datasheet |
Box | KBL | Active | Feed Through | - | 20 | 1 | - | Screw | 32 A | 500V | 30 A | 300V | 10-22 AWG | 0.2-4mm² | - | Beige |
![]() |
2552150000FEED-THROUGH TERMINAL BLOCK, PUS |
4,439 | 12.61 |
RFQ |
![]() Datasheet |
Box | W | Active | Feed Through | - | 2 | 1 | 16.0mm | Push In, Spring | 105 A | 880V | 113 A | 1000V | 2-12 AWG | 10-35mm² | - | Blue |
![]() |
1023.2CONN TERM BLK FEED THRU 10-22AWG |
4,423 | 13.12 |
RFQ |
![]() Datasheet |
Box | RKD | Active | Feed Through | - | 4 | 2; Connected | 12.0mm | Screw | 10 A | 30V | 30 A | 300V | 10-22 AWG | 0.2-4mm² | Varistor | Beige |
![]() |
1024.2CONN TERM BLK FEED THRU 10-22AWG |
3,795 | 13.12 |
RFQ |
![]() Datasheet |
Box | RKD | Active | Feed Through | - | 4 | 2; Connected | 12.0mm | Screw | 10 A | 60V | 30 A | 300V | 10-22 AWG | 0.2-4mm² | Varistor | Beige |
![]() |
1029.2CONN TERM BLK FEED THRU 10-22AWG |
4,707 | 13.12 |
RFQ |
![]() Datasheet |
Box | RKD | Active | Feed Through | - | 4 | 2; Connected | 12.0mm | Screw | 10 A | 75V | 30 A | 300V | 10-22 AWG | 0.2-4mm² | Varistor | Beige |
![]() |
2002-1911/1000-5422-CONDUCTOR FUSE TERMINAL BLOCK; |
3,153 | 14.75 |
RFQ |
![]() Datasheet |
Box | TOPJOB®S | Active | Disconnect | Fuse | 2 | 1 | 6.2mm | Push In, Spring | 6.3 A | 250V | 6.3 A | 65V | 12-22 AWG | 0.25-4mm² | LED | Gray |
![]() |
280-586/281-4964-CONDUCTOR SENSOR SUPPLY TERMIN |
4,642 | 14.75 |
RFQ |
![]() Datasheet |
Box | - | Active | Isolated | - | 2 | 2; Connected | 5.0mm | Push In, Spring | 20 A | - | - | - | 12-28 AWG | 0.08-2.5mm² | LED, Resistor | Gray |
![]() |
0667420000SAKS 3/35 1X1/4 KRG BN |
4,750 | 14.19 |
RFQ |
Bulk | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
![]() |
8013840000CONN TERM BLK DISCONN 12-26AWG |
4,828 | 14.21 |
RFQ |
![]() Datasheet |
Bulk | W | Active | Disconnect | - | 4 | 2; Connected | 5.1mm | Screw | - | - | - | - | 12-26 AWG | 0.5-4mm² | Glow Lamp | Beige |