Фотографии | Производитель. Часть # | Доступность | Цены | Количество | Таблицы данных | Packaging | Series | ProductStatus | Type | DisconnectType | NumberofPositions | NumberofLevels | Terminal-Width | TerminationStyle | Current-IEC | Voltage-IEC | Current-UL | Voltage-UL | WireGaugeorRange-AWG | WireGaugeorRange-mm² | Features | Color |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
1078.5FUSE DISCONNECT TERMINAL |
7,685 | 6.33 |
RFQ |
![]() Datasheet |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 500V | 16 A | 600V | 12-22 AWG | 0.2-4mm² | - | Blue |
![]() |
2190.3FUSE DISCONNECT TERMINAL |
5,412 | 6.33 |
RFQ |
![]() Datasheet |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 400V | 16 A | 600V | 12-22 AWG | 0.2-4mm² | - | Orange |
![]() |
2190.4FUSE DISCONNECT TERMINAL |
9,007 | 6.33 |
RFQ |
![]() Datasheet |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 400V | 16 A | 600V | 12-22 AWG | 0.2-4mm² | - | Black |
![]() |
2190.5FUSE DISCONNECT TERMINAL |
8,798 | 6.33 |
RFQ |
![]() Datasheet |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 400V | 16 A | 600V | 12-22 AWG | 0.2-4mm² | - | Blue |
![]() |
2190.9FUSE DISCONNECT TERMINAL |
6,968 | 6.33 |
RFQ |
![]() Datasheet |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 400V | 16 A | 600V | 12-22 AWG | 0.2-4mm² | - | Red |
![]() |
2191.5FUSE DISCONNECT TERMINAL |
8,449 | 6.33 |
RFQ |
![]() Datasheet |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 400V | 16 A | 600V | 12-22 AWG | 0.2-4mm² | - | Blue |
![]() |
1018100000CONN TERM BLK DISCONNECT 8-20AWG |
6,340 | 6.09 |
RFQ |
![]() Datasheet |
Bulk | W | Active | Disconnect | Switch, Slide | 2 | 1 | 7.9mm | Screw | 41 A | 500V | 45 A | 300V | 8-20 AWG | 0.5-10mm² | - | Beige |
![]() |
CPST1.5/4L-110-240VDIN TERM BLK, PUSH-IN, SENSOR & |
6,354 | 6.34 |
RFQ |
![]() Datasheet |
Box | CP | Active | Feed Through | - | 4 | 2 | 3.5mm | Push In, Spring | 13.5 A | 250V | 15 A | 150V | 14-24 AWG | 0.2-1.5mm² | LED Indicator | Gray |
![]() |
CPST1.5/4L-6-60VDIN TERM BLK, PUSH-IN, SENSOR & |
7,750 | 6.34 |
RFQ |
![]() Datasheet |
Box | CP | Active | Feed Through | - | 4 | 2 | 3.5mm | Push In, Spring | 13.5 A | 250V | 15 A | 150V | 14-24 AWG | 0.2-1.5mm² | LED Indicator | Gray |
![]() |
0412760000CONN TERM BLK DISCONN 12-26AWG |
9,687 | 6.10 |
RFQ |
![]() Datasheet |
Bulk | SAK | Active | Disconnect | Switch, Knife | 2 | 1 | 6.5mm | Screw | 10 A | 400V | 10 A | 300V | 12-26 AWG | 0.5-4mm² | - | Beige |
![]() |
0412360000CONN TERM BLK DISCONN 12-22AWG |
5,187 | 6.10 |
RFQ |
Bulk | SAK | Active | Disconnect | Switch, Knife | 2 | 1 | 6.5mm | Screw, Solder | 10 A | 250V | 10 A | 300V | 12-22 AWG | 1.5-4mm² | - | Beige | |
![]() |
2104-12012-CONDUCTOR THROUGH TERMINAL BLO |
6,875 | 6.36 |
RFQ |
![]() Datasheet |
Box | TOPJOB®S | Active | Feed Through | - | 2 | 1 | 6.2mm | Push In, Spring | 40 A | 800V | 30 A | 600V | 10-20 AWG | 0.5-6mm² | - | Gray |
![]() |
2104-12042-CONDUCTOR THROUGH TERMINAL BLO |
8,812 | 6.36 |
RFQ |
![]() Datasheet |
Box | TOPJOB®S | Active | Feed Through | - | 2 | 1 | 6.2mm | Push In, Spring | 40 A | 800V | 30 A | 600V | 10-20 AWG | 0.5-6mm² | - | Blue |
![]() |
2104-52042-CONDUCTOR THROUGH TERMINAL BLO |
8,438 | 6.36 |
RFQ |
![]() Datasheet |
Box | TOPJOB®S | Active | Feed Through | - | 2 | 1 | 6.2mm | Push In, Spring | 40 A | 800V | 30 A | 600V | 10-20 AWG | 0.5-6mm² | - | Blue |
![]() |
2104-52012-CONDUCTOR THROUGH TERMINAL BLO |
5,754 | 6.36 |
RFQ |
![]() Datasheet |
Box | TOPJOB®S | Active | Feed Through | - | 2 | 1 | 6.2mm | Push In, Spring | 40 A | 800V | 30 A | 600V | 10-20 AWG | 0.5-6mm² | - | Gray |
![]() |
1934800000WTQ 6/1 EN STB |
8,456 | 6.12 |
RFQ |
Bulk | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
![]() |
7910360000WTR 4 SL/EN W/O STB WM BG |
5,020 | 6.14 |
RFQ |
Bulk | * | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | |
![]() |
3283.2THREE-CONDUCTOR INSTALLATION TER |
9,731 | 6.40 |
RFQ |
![]() Datasheet |
Box | FDLI | Active | Disconnect, Feed Through, Isolated | Switch, Lever | 5 | 3; 1 Grounded | 5.1mm | Push In | 18 A | 400V | - | - | 10-26 AWG | 0.2-4mm² | - | Beige |
![]() |
1190.2FUSE DISCONNECT TERMINAL |
8,594 | 6.41 |
RFQ |
![]() Datasheet |
Box | STK | Active | Disconnect | Fuse, Lever | 2 | 1 | 8.0mm | Screw | 6.3 A | 500V | 16 A | 600V | 12-22 AWG | 0.2-4mm² | - | Beige |
![]() |
CAFL4U(L)/110UIFUSETERM WLED16A 600V 22-10AWG 9 |
8,779 | 6.41 |
RFQ |
Bulk | - | Active | Disconnect | Fuse, Lever | 2 | 1 | 9.0mm | Screw | 6.3 A | 1000V | 16 A | 600V | 10-22 AWG | 0.2-4mm² | LED Indicator | - |